Outdoor Expulsion Drop-out Type Distribution Superior Porcelain and Polymer Fuse Cutout Series 27kv-33kv
Overview Outdoor Expulsion Drop-out Type Distribution Superior Porcelain and Polymer Fuse Cutout Series 27kv-33kv Produc;
Basic Info
Model NO. | FCR |
Breaking Capacity | High |
Type | Temperature Fuse |
Usage | High Voltage |
Shape | Spiral |
Standard | VDE |
Material | Ceramic Body |
Voltage | 38kv |
Current | 100A-200A |
Transport Package | Standard Export Packing |
Specification | CE |
Trademark | Powtech |
Origin | China |
HS Code | 8538900000 |
Production Capacity | 5000PCS/Month |
Product Description
Outdoor Expulsion Drop-out Type Distribution Superior Porcelain and Polymer Fuse Cutout Series 27kv-33kvProduct Description
The primary purpose of any fuse cutouts is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.
Detailed Photos Product Parameters
No. | Type | Rated voltage (kV) | Rated current (A) | Breaking current (A) | Impulse voltage (BIL) | Power-frequency with stand voltage (KV) | Leakage distance (MM) | Weight(KG) | Dimensions (CM) |
1 | (H)RW11 | 10(F) | 100(200) | 6300 | 110 | 42 | 260 | 7.5 | 48x32x27 |
2 | (H)RW10 | 10(F) | 100(200) | 8000 | 110 | 42 | 260 | 9.5 |
No. | Type | Rated voltage (kV) | Rated current (A) | Breaking current (A) | Impulse voltage (BIL) | Power-frequency with stand voltage (KV) | Leakage distance (MM) | Weight(KG) | Dimensions (CM) |
1 | GWNCX1 | 12 | 100 | 6300 | 125 | 42 | 260 | 7.5 | 58x32x11.5 |
2 | GWNCX2 | 12 | 200 | 12500 | 125 | 42 | 260 | 7.5 |
No. | Type | Rated voltage (kV) | Rated current (A) | Breaking current (A) | Impulse voltage (BIL) | Power-frequency withstand voltage (KV) | Leakage distance (MM) | Weight(KG) | Dimensions (CM) |
1 | (H)FCR | 11/15(F) | 100 | 6300 | 110 | 42 | 260 | 7.5 | 58x32x11.5 |
2 | (H)FCR | 11/15(F) | 200 | 12500 | 110 | 42 | 260 | 7.5 |
No. | Type | Rated voltage (kV) | Rated current (A) | Breaking current (A) | Impulse voltage (BIL) | Power-frequency withstand voltage (KV) | Leakage distance (MM) | Weight (KG) | Dimensions (CM) |
1 | (H)FCR | 24/33(F) | 100 | 6300 | 150 | 70 | 750 | 12 | 58x38.5x14.5 |
2 | (H)FCR | 24/33(F) | 200 | 12500 | 150 | 70 | 750 | 12 |
No. | Type | Rated voltage (kV) | Rated current (A) | Breaking current (A) | Impulse voltage (BIL) | Power-frequency withstand voltage (KV) | Leakage distance (MM) | Weight (KG) | Dimensions (CM) |
1 | (H)FCR | 33/36(F) | 100 | 10000 | 170 | 95 | 1000 | 14 | 70.5x39.5x14.5 |
2 | (H)FCR | 33/36(F) | 200 | 12500 | 170 | 95 | 1000 | 14 |